Regular priceCHF96.60
/
- Single Use Real-Time Shipment Data Logger
- Ensured Runtime of 110 Days
- Internal Temperature Sensor is 100% Calibrated
- Ideally Complements existing USB Data Logger Portfolio
- Automatic Flight Detection and no need to declare as Dangerous Goods
- Uploads measured Data Automatically to elproCLOUD
- ***Check Country List to ensure Roaming and Cellular Network Coverage***
Type: | Wireless Data logger with internal temperature sensor |
Application Area: | Transport Monitoring: Global distribution of temperature sensitive products |
Sensors: |
High accuracy digital temperature sensor | Geographical location | Light | Tilt |
Measurement Range: |
0 °C.. + 55 °C (only short term use above and below application range allowed) |
Measurement Accuracy: |
Internal Sensor:
|
Measurement Interval: | 15 to 60 minutes, user configurable via elproCLOUD |
Cellular Network: | LTE-M and NB-IoT |
Communication Interval: | 2 to 6 hours, user configurable via elproCLOUD, event-driven immediate communication (e.g. excursion, last will) No communication in frozen application (measurement data is buffered and is transmitted with next communication) |
Measurement Capacity: | 31.000 measurement values (equals 322 days with 15 min measurement interval) |
Certificate: | Manufacturer validation certificate per delivery, production validation and 3-point calibration certificate (ILAC/NIST/ISO 17025 tracable) pre ID number via compliance.elpro.com, additional customer-specific calibration points optionally available. |
Reporting: | Real-time visibility and notification about temperature excursions or occurrences via elproCLOUD |
Case | Dimension | Weight: | ABS plastic material | 100 × 65 × 19 mm (3.9 × 2.5 × 0.7 in) | 125 g (4.4 oz) |
Conformity: | CE | FCC | UKCA | ICES | RoHS | UN38.3 | WEEE | NCC | RSM | TDRA | ENACOM | IMDA | MIC | ACMA/RCM |
Standards: | EN 12830 | RTCA DO-160 (EMC) | GAMP5 |
Technical Specification LIBERO GS